Last Modified: 11-29-2007 |
1.6 J |
|
Service Category: Vehicle Exterior |
Section: Window/Glass |
|
Model Year: 2008 |
Model: Sequoia |
Doc ID: RM000003F59000X |
|
Title: WINDOW / GLASS: POWER WINDOW CONTROL SYSTEM: DESCRIPTION (2008 Sequoia) |
|
Front Passenger Side Power Window Auto Up / Down Function does not Operate with Front Passenger Side Power Window Switch
|
DESCRIPTION
If the AUTO UP/DOWN function does not operate, the cause may be one or more of the following:
-
The ECU in the power window regulator motor determines that the power window regulator motor has not been initialized.
-
The power window regulator switch has a malfunction.
-
The Hall-IC in the power window regulator motor has a malfunction.
-
The wiring between the power window regulator switch and the power window regulator motor is open or short.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
(a) Check for DTCs
.
Result
|
Result
|
Proceed to
|
|
DTC is not output
|
A
|
|
B2311 is output
|
B
|
|
B2312 is output
|
C
|
|
B2313 is output
|
D
|
|
LIN communication system DTCs are output
|
E
|
| A |
|
|
|
2.
|
CHECK MANUAL UP / DOWN FUNCTION
|
(a) Check that the manual UP/DOWN function using the power window regulator switch can operate the front passenger side door power window
.
OK:
Manual UP/DOWN function operates.
| OK |
|
|
|
3.
|
READ VALUE USING TECHSTREAM (FRONT POWER WINDOW REGULATOR MOTOR RH)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / P-Door Motor / Data List.
(e) According to the display on the Techstream, read the Data List.
P-Door Motor
|
Tester Display
|
Measurement Item/Range
|
Normal Condition
|
Diagnostic Note
|
|
P Door P/W Auto SW
|
Front passenger side power window auto UP/DOWN switch signal / ON or OFF
|
ON: Front passenger side power window auto UP/DOWN switch operated
OFF: Front passenger side power window switch not operated
|
-
|
OK:
The Techstream display changes when front passenger side power window switch is operated.
| OK |
|
|
|
4.
|
CHECK HARNESS AND CONNECTOR (FRONT POWER WINDOW SWITCH RH - FRONT POWER WINDOW MOTOR RH)
|
|
(a) Disconnect the L2 front power window regulator switch assembly RH connector.
|
(b) Disconnect the L3 front power window regulator motor assembly RH connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
L2-8 (AUTO) - L3-4 (AUTO)
|
Always
|
Below 1 Ω
|
|
L2-8 (AUTO) - Body ground
|
Always
|
10 kΩ or higher
|
(d) Reconnect the front power window regulator motor assembly RH connector.
(e) Reconnect the front power window regulator switch assembly RH connector
| OK |
|
|
|
5.
|
INSPECT FRONT POWER WINDOW REGULATOR SWITCH ASSEMBLY RH
|
|
(a) Remove the I3 front power window regulator switch assembly RH
.
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Switch Condition
|
Specified Condition
|
|
8 (AUTO) - 1 (GND)
|
AUTO UP/DOWN operation
|
Below 1 Ω
|
(c) Reinstall the front power window regulator switch assembly RH.
| OK |
|
|
|